977 resultados para ocular parameters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE To investigate changes in the characteristics of the corneal optics, total optics, anterior biometrics and axial length of the eye during a near task, in downward gaze, over 10 min. METHODS Ten emmetropes (mean - 0.14 ± 0.24 DS) and 10 myopes (mean - 2.26 ± 1.42 DS) aged from 18 to 30 years were recruited. To measure ocular biometrics and corneal topography in downward gaze, an optical biometer (Lenstar LS900) and a rotating Scheimpflug camera (Pentacam HR) were inclined on a custom built, height and tilt adjustable table. The total optics of the eye were measured in downward gaze with binocular fixation using a modified Shack-Hartmann wavefront sensor. Initially, subjects performed a distance viewing task at primary gaze for 10 min to provide a "wash-out" period for prior visual tasks. A distance task (watching video at 6 m) in downward gaze (25°) and a near task (watching video on a portable LCD screen with 2.5 D accommodation demand) in primary gaze and 25°downward gaze were then carried out, each for 10 min in a randomized order. During measurements, in dichoptic view, a Maltese cross was fixated with the right (untested) eye and the instrument’s fixation target was fixated with the subject’s tested left eye. Immediately after (0 min), 5 and 10 min from the commencement of each trial, measurements of ocular parameters were acquired in downward gaze. RESULTS Axial length exhibited a significant increase with downward gaze and accommodation over time (p<0.05). The greatest axial elongation was observed in downward gaze with 2.5 D accommodation after 10 min (mean change from baseline 23±3 µm). Downward gaze also caused greater changes in anterior chamber depth (ACD) and lens thickness (LT) with accommodation (ACD mean change -163±12µm at 10 min; LT mean change 173±17 µm at 10 min) compared to primary gaze with accommodation (ACD mean change -138±12µm at 10 min; LT mean change 131±15 µm at 10 min). Both corneal power and total ocular power changed by a small but significant amount with downward gaze (p<0.05), resulting in a myopic shift (~0.10 D) in the spherical power of the eye compared with primary gaze. CONCLUSION The axial length, anterior biometrics and ocular refraction change significantly with accommodation in downward gaze as a function of time. These findings provide new insights into the optical and bio-mechanical changes of the eye during typical near tasks.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose The present study aimed to review the effect of dehydration during Ramadan fasting on the health and ocular parameters leading to changes in eye function. Methods Articles included in the study were taken from PubMed, Ovid, Web of Science and Google Scholar up to 2014. Related articles were also obtained from scientific journals on fasting and vision system. Results Dehydration and nutrition changes in Ramadan cause an increase in tear osmolarity, ocular aberration, anterior chamber depth, IOL measurement, central corneal thickness, retinal and choroidal thicknesses, and also a decrease in IOP, tear secretion, and vitreous thickness. Conclusion Much research related to the effect of dehydration on ocular parameters during Ramadan fasting exists. The findings reveal association with significant changes on ocular parameters. Thus, it seems requisite to have a comprehensive study on "fasting and ocular parameters”, which will be helpful in making decisions and giving plan to the patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness. ----- Methods: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3-7 hours over a 24-hour period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analysed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Intraocular pressure and axial length were also measured at each measurement session. Repeated measures ANOVA were used to investigate diurnal change in these parameters. Analysis of covariance was used to examine associations between the measured ocular parameters. ----- Results: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180° at this time. A significant swelling of the cornea (p < 0.0001) was also found to occur immediately after waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature. ----- Conclusions: Significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea were typically evident upon waking. The observed non-uniform regional corneal thickness changes resulted in a steepening of the posterior cornea, and a flattening of the anterior cornea to occur at this time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to investigate the influence of water loading upon intraocular pressure (IOP), ocular pulse amplitude (OPA) and axial length. Twenty one young adult subjects who were classified based on their spherical equivalent refraction as either myopes (n=11), or emmetropes (n=10) participated. Measures of IOP, OPA and ocular biometrics were collected before, and then 10, 15, 25 and 30 minutes following the ingestion of 1000 ml of water. Significant increases in both IOP and OPA were found to occur following water loading (p<0.0001), with peaks in both parameters occurring at 10 minutes after water loading (mean ± SEM increase of 2.24 ± 0.31 mmHg in IOP and 0.46 ± 0.06 mmHg in OPA). Axial length was found to reduce significantly following water loading (p=0.0005), with the largest reduction in axial length evident 10 minutes after water drinking (mean decrease 12 ± 3 µm). A significant time by refractive error group interaction (p=0.048) was found in axial length, indicative of a different pattern of change in eye length following water loading between the myopic and emmetropic populations. The largest difference in axial length change was evident at 10 minutes after water loading with a 17 ± 5 µm reduction in axial length evident in the myopes and only a 6 ± 2 µm reduction in the emmetropes. These findings illustrate significant changes in ocular parameters in young adult subjects following water loading.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Magnetic Resonance Imaging was used to study changes in the crystalline lens and ciliary body with accommodation and aging. Monocular images were obtained in 15 young (19-29 years) and 15 older (60-70 years) emmetropes when viewing at far (6m) and at individual near points (14.5 to 20.9 cm) in the younger group. With accommodation, lens thickness increased (mean±95% CI: 0.33±0.06mm) by a similar magnitude to the decrease in anterior chamber depth (0.31±0.07mm) and equatorial diameter (0.32±0.04mm) with a decrease in the radius of curvature of the posterior lens surface (0.58±0.30mm). Anterior lens surface shape could not be determined due to the overlapping region with the iris. Ciliary ring diameter decreased (0.44±0.17mm) with no decrease in circumlental space or forward ciliary body movement. With aging, lens thickness increased (mean±95% CI: 0.97±0.24mm) similar in magnitude to the sum of the decrease in anterior chamber depth (0.45±0.21mm) and increase in anterior segment depth (0.52±0.23mm). Equatorial lens diameter increased (0.28±0.23mm) with no change in the posterior lens surface radius of curvature. Ciliary ring diameter decreased (0.57±0.41mm) with reduced circumlental space (0.43±0.15mm) and no forward ciliary body movement. Accommodative changes support the Helmholtz theory of accommodation including an increase in posterior lens surface curvature. Certain aspects of aging changes mimic accommodation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose.: To develop three-surface paraxial schematic eyes with different ages and sexes based on data for 7- and 14-year-old Chinese children from the Anyang Childhood Eye Study. Methods.: Six sets of paraxial schematic eyes, including 7-year-old eyes, 7-year-old male eyes, 7-year-old female eyes, 14-year-old eyes, 14-year-old male eyes, and 14-year-old female eyes, were developed. Both refraction-dependent and emmetropic eye models were developed, with the former using linear dependence of ocular parameters on refraction. Results.: A total of 2059 grade 1 children (boys 58%) and 1536 grade 8 children (boys 49%) were included, with mean age of 7.1 ± 0.4 and 13.7 ± 0.5 years, respectively. Changes in these schematic eyes with aging are increased anterior chamber depth, decreased lens thickness, increased vitreous chamber depth, increased axial length, and decreased lens equivalent power. Male schematic eyes have deeper anterior chamber depth, longer vitreous chamber depth, longer axial length, and lower lens equivalent power than female schematic eyes. Changes in the schematic eyes with positive increase in refraction are decreased anterior chamber depth, increased lens thickness, decreased vitreous chamber depth, decreased axial length, increased corneal radius of curvature, and increased lens power. In general, the emmetropic schematic eyes have biometric parameters similar to those arising from regression fits for the refraction-dependent schematic eyes. Conclusions.: The paraxial schematic eyes of Chinese children may be useful for myopia research and for facilitating comparison with other children with the same or different racial backgrounds and living in different places.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To compare lens dimensions and refractive index distributions in type 1 diabetes and age-matched control groups. Methods: There were 17 participants with type 1 diabetes, consisting of two subgroups (7 young [23 ± 4 years] and 10 older [54 ± 4 years] participants), with 23 controls (13 young, 24 ± 4 years; 10 older, 55 ± 4 years). For each participant, one eye was tested with relaxed accommodation. A 3T clinical magnetic resonance imaging scanner was used to image the eye, employing a multiple spin echo (MSE) sequence to determine lens dimensions and refractive index profiles along the equatorial and axial directions. Results: The diabetes group had significantly smaller lens equatorial diameters and larger lens axial thicknesses than the control group (diameter mean ± 95% confidence interval [CI]: diabetes group 8.65 ± 0.26 mm, control group 9.42 ± 0.18 mm; axial thickness: diabetes group 4.33 ± 0.30 mm, control group 3.80 ± 0.14 mm). These differences were also significant within each age group. The older group had significantly greater axial thickness than the young group (older group 4.35 ± 0.26 mm, young group 3.70 ± 0.25 mm). Center refractive indices of diabetes and control groups were not significantly different. There were some statistically significant differences between the refractive index fitting parameters of young and older groups, but not between diabetes and control groups of the same age. Conclusions: Smaller lens diameters occurred in the diabetes groups than in the age-matched control groups. Differences in refractive index distribution between persons with and without diabetes are too small to have important effects on instruments measuring axial thickness.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate reproducibility and precision of ocular measurements by digital photograph analysis, in addition to the transformation of the measures according to the individual iris diameter as an oculometric reference. Methods: Twenty-four eyes have been digitally photographed in a standardized way at two distances. Two researchers have analyzed these printed images using a caliper and these digital forms by ImageJ 1.37 (TM). Several external ocular parameters were estimated (mm and as iris diameter) and methods of measurement compared regarding their precision, agreement and correlation. Results: Caliper and digital analysis of oculometric measures provided significant agreement and correlation, nevertheless the precision of digital measures was higher. The estimates of numeric transformation from oculometric measures according to individual iris diameter resulted in great correlation to caliper measures and high agreement when compared to different distances of taking the photographs. Conclusions: Facial digital photographs allowed oculometric precise and reproducible estimates, endorsing clinical research usefulness. Using iris diameter as individual oculometric reference disclosed high reproducibility when facial photographs were taken at different distances.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To evaluate the clinical application of implant of the canine cryopreserved amniotic membrane (DMEM plus DMSO 1:1) and 360° conjunctival flap in the treatment of progressive corneal ulceration. 10 dogs of the different breeds, males and females, aging four months to four years old with deep corneal ulceration and different clinical progression were divided in two groups: G1=360° conjunctival graft (n=5) and G2=implant of amniotic membrane, sutured at the edge of the ulcer with epithelial side facing up, associated with the third eyelid flap (n=5). The comparative analysis between groups was: complications, blepharospasm, ocular secretion, corneal vascularization, epithelial defect and corneal opacification in six moments (first emergency care, surgery and 3, 7, 15 and 30 days of postoperative). Without epithelial defect was evaluated quality of the scar. It was used score scale for subjective to qualify of the ocular signs. In G1, it was observed the non-adherence of the conjunctival graft to the ulcer (n=2), dehiscence of the suture (n=2), anterior synechia (n=2) and intense chemosis (n=1). In G2, it was not observed these complications. It was not significant difference between the groups to others ocular parameters, but it was different among the start and end moments of the same groups (ocular secretion, corneal vascularization, epithelial defect). The corneal opacity was more intense in G1. According to the clinical results, the cryopreserved amniotic membrane implant proved to be as effective in the corneal ulceration in comparison to the 360° conjunctival flap, because probably, the membrane promoted a trophic support for epithelialization, anti-inflamatory effect associated with important to the end result phenotype.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the correlation of the mean curvature and shape factors of both corneal surfaces for different corneal diameters measured with the Scheimpflug photography–based system in keratoconus eyes. Methods: A total of 61 keratoconus eyes of 61 subjects, aged 14 to 64 years, were included in this study. All eyes received a comprehensive ophthalmologic examination including anterior segment and corneal analysis with the Sirius system (CSO): anterior and posterior mean corneal radius for 3, 5, and 7 mm (aKM, pKM), anterior and posterior mean shape factor for 4.5 and 8 mm (ap, pp), central and minimal corneal thickness, and anterior chamber depth. Results: Mean aKM/pKM ratio around 1.20 (range, 0.95–1.48) was found for all corneal diameters (P = 0.24). Weak but significant correlations of this ratio with pachymetric parameters were found (r between −0.28 and −0.34, P < 0.04). The correlation coefficient between aKM and pKM was ≥0.92 for all corneal diameters. A strong and significant correlation was also found between ap and pp (r ≥ 0.86, P < 0.01). The multiple regression analysis revealed that central pKM was significantly correlated with aKM, central corneal thickness, anterior chamber depth, and spherical equivalent (R2 ≥ 0.88, P < 0.01) and that 8 mm pp was significantly correlated with 8 mm ap and age (R2 = 0.89, P < 0.01). Conclusions: Central posterior corneal curvature and shape factor in the keratoconus eye can be consistently predicted from the anterior corneal curvature and shape factor, respectively, in combination with other anatomical and ocular parameters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods: This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickness (CCT) and anterior chamber depth were measured by anterior segment optical coherence tomography (Visante). Results: Mean (±SD) CH and CRF were 12.12 (±1.71) and 12.30 (±1.89) mm Hg, respectively. Mean (±SD) CCT was 542.68 (±37.20) μm and mean (±SD) spherical equivalent was +0.14 (±3.41) diopters. A positive correlation was found between CH and CRF (p < 0.001), and both correlated as well with CCT (p < 0.0001). Corneal resistance factor was found to decrease with increasing age (p = 0.01). Lower levels of CH were associated with longer AL and more myopia (p < 0.001 and p = 0.001, respectively). Higher values of CH were associated with increasing hyperopia. Significant differences in CH were found between emmetropic and myopic groups (p < 0.001) and between myopic and hyperopic groups (p = 0.011). There were also significant differences in CRF between emmetropic and myopic groups (p = 0.02). Multiple linear regression analysis showed that lower CH and CRF significantly associated with thinner CCT, longer AL, and flatter corneal curvature. Conclusions: The Ocular Response Analyzer corneal biomechanical properties seem to be compromised in myopia from an early age, especially in high myopia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Optometrists are becoming more integrally involved in the diagnosis of and care for glaucoma patients in the UK. The correlation of apparent change in non contact tonometry (NCT) IOP measurement and change in other ocular parameters such as refractive error, corneal curvature, corneal thickness and treatment zone size (data available to optometrists after LASIK) would facilitate care of these patients. Setting: A UK Laser Eye Clinic. Methods: This is a retrospective study study of 200 sequential eyes with myopia with or without astigmatism which underwent LASIK using a Hansatome and an Alcon LADARvision 4000 excimer laser. Refraction keratometry, pachymetry and NCT IOP mesurements were taken before treatmebnt and agian 3 months after treatment. The relationship between these variables anfd teh treatment zones were studied using stepwise multiple regression analysis. Results: There was a mean difference of 5.54mmHg comnparing pre and postoperative NCT IOP. IOP change correlates with refractive error change (P < 0.001), preoperative corneal thickness (P < 0.001) and treatment zone size (P = 0.047). Preoperative corneal thickness correlates with preoperative IOP (P < 0.001) and postoperative IOP (P < 0.001). Using these correlations, the measured difference in NCT IIOP can be predicted preoperatively or postoperatively using derived equations.Conclusion: There is a significant reduction in measured NCT IOP after LASIK. The amount of reduction can be calculated using data acquired by optometrists. This is helpful for opthalmologists and optometrists who co-manage glaucoma patients who have had LASIK or with glaucoma pateints who are consideraing having LASIK.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study investigated the central and peripheral corneal characteristics of groups of subjects from 20 to 90 years of age to assist the understanding of ageing changes in the cornea, and to see whether relationships between ocular parameters were revealed. After age 45 the corneal horizontal radius of curvature gradually decreased with age. This trend was shown by the Aston University subjects (group B). The effect was very significant for the hospital patients undergoing biometry before cataract extraction operation (group D). Vertical radius of curvature showed a slight decrease with age after age 45, but similar to corneal eccentricity, this showed no significant age effect. Corneal astigmatism progressed from with the rule towards against the rule, particularly after age 60. The shift seemed mainly due to the decreasing horizontal corneal curvature. In biometry no significant age relation was found for axial length, but a significant relation was found between curvature and axial length in the larger group D. Lens thickness showed a very significant relation to age and to axial length, but no significant relation to corneal curvature. Anterior chamber depth showed a very significant relation to age, lens thickness and axial length, but no significant relation to corneal curvature. A significant age effect was found for corneal thickness decreasing with age for the central, nasal and temporal regions of the right eye. Analysis of the biometry results indicated the influence of two major factors. Firstly, the natural growth of the eye in youth, leading to greater values of axial length, radius of corneal curvature, lens thickness and anterior chamber depth. Secondly, the typical ageing changes where the increasing lens thickness caused a reduction in anterior chamber depth. The decrease in corneal thickness with age shown in some corneal regions may be a sign of ageing changes in the tissue proteins and hydration balance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Soft contact lenses for continuous wear require the use of cleaning regimes which utilise hydrogen peroxide systems or multipurpose cleaning solutions (MPS). The compositions of MPS are becoming increasingly complex and often include disinfectants, cleaning agents, preservatives, wetting agents, demulcents, chelating and buffering agents. Recent research on solution–lens interactions has focused on specific ocular parameters such as corneal staining. However the effect of a solution on the lens, particularly silicone hydrogel lenses, itself has received less attention. The purpose of this work was to establish and understand the effects that care solutions have on selected bulk and surface material properties. Methods: Selected bulk and surface properties of each material (etafilcon A, vifilcon A, balafilcon A, senofilcon A, lotrafilcon A and lotrafilcon B, galyfilcon A) were measured after a 24 h soak in a variety of care solutions. Additionally the lenses were soaked for 24 h in hyperosmolar (680 mOsm L-1) and hyposmolar (170 mOsm L-1) PBS. A bulk property parameter the total diameter (TD) was measured using an Optimec contact lens analyser. The surface property related CoF of soaked lenses was measured on a nano-tribometer with conditions of load 30 mN, at a distance of 20 mm and speed 30 mm/min. Results: In terms of bulk properties, change is related to the EWC of the lens, the higher the EWC of the lens the greater the TD changes. Silicone hydrogel lenses have EWCs of <47% and little or no TD changes were observed; lotrafilcon A exhibited no change irrespective of the cleaning solution. Conventional contact lenses have higher EWCs (58% for etafilcon A and 55% for vifilcon A) and the TD was seen to change to a greater extent, for example the etafilcon A material in ReNu MPS had an increase to 14.45± 0.07 mm from the cited 14.2 mm. Other lenses increased or decreased in TD depending on the solution used. The osmolarity of the solution although important is not the only factor governing change in the TD, for example soaking senofilcon A in hyperosmolar PBS (680 mOsm L-1) for 24 h increased the TD of the lens (+0.25 ± 0.07 mm), however when the same lens type was soaked for 24 h in a MPS with a lower osmolarity there was a similar effect. Biotribology measurements demonstrated that some solution–lens combinations can reduce the CoF by 55%, when compared with biotribology with the native packing solution. An increase in the CoF was observed for other solution–lens combinations. Conclusions: There is a dramatic difference in bulk and surface performance of specific lens materials with particular care solutions. Individual components of the care solutions have effects on the bulk and surface properties of contact lenses. The affects are not as great with the silicone hydrogel as compared with conventional hydrogels.